Guardian Industries, with Seeq · May – August 2022

Furnace pressure diagnostics for float glass lines

  • Seeq Workbench
  • Industrial analytics
  • Process monitoring
  • Dashboards
Challenge
Give plant engineers a consistent way to detect unhealthy furnace pressure conditions across float glass lines worldwide, replacing ad-hoc spreadsheet investigations.
Solution
Reusable Seeq analyses for negative-pressure duration, pressure differences between furnace zones and firing-side reversals, published as Organizer dashboards.
Result
Deployed across multiple production lines with minimal configuration, giving near-real-time visibility of pressure anomalies.
Rendering of a float glass line showing molten glass flowing from the furnace onto the tin bath
Rendering of a float glass line showing molten glass flowing from the furnace onto the tin bath

Objective

Give engineers a way to monitor and respond to harmful pressure conditions on float lines, improving asset health and operational consistency while cutting manual investigation.

Negative furnace pressure

Logic that detects and quantifies the daily duration of negative pressure per furnace, with custom thresholds flagged through Seeq’s scorecard. One furnace was found to run more than 60 minutes of negative pressure in a single day, a figure that had been hard to track before.

Scorecard of daily negative-pressure minutes per furnace
Scorecard of daily negative-pressure minutes per furnace

Pressure differences between zones

Mapped real-time pressure across the left, right and process-variable zones, and calculated the deltas between the furnace, working end and tin bath. At one site the working-end pressure sat above the tin bath for most of a month, pointing to a flow imbalance or sensor drift.

Trend comparing furnace, working-end and tin-bath pressure over a month
Trend comparing furnace, working-end and tin-bath pressure over a month

Firing-side reversal detection

Inferred which side the furnace was firing on from the gas-flow differential, defined a transition state with a one-minute buffer around each reversal, and trended the minimum and maximum pressure through those windows. This exposed cyclical behaviour and pressure dips during transitions at specific plants.

Trend of pressure during left and right firing-side transitions
Trend of pressure during left and right firing-side transitions

Deployment

Everything was built in Seeq Workbench and published through Organizer dashboards. Because the logic is asset-group based, the same diagnostic framework was deployed across sites with minimal configuration.

Outcome

  • Replaced ad-hoc spreadsheet investigations with automated visual diagnostics.
  • Near-real-time visibility of negative pressure and firing reversals.
  • Earlier detection of imbalances, before they escalate.
  • One set of tools, deployed globally, with consistent diagnostics and reporting.